Version-specific research record
EdgeConneX TOR01 / EDCTOR01
EdgeConneX · Toronto, Ontario
Record on-122 · 2026-10-06-83c11c799ab4-public-2026-10-06
Historical published edition. Do not treat these as newer or additional facts. Evidence reviewed through 2026-10-06. Edition publication date: 2026-10-06.
Research record, not a building count. Campus and phase overlap may exist; do not add capacity values.
Current record profile · This edition’s record JSON · Edition overview
Identity provenance
- city: EdgeConneX, Cogent Communications
- disposition: EdgeConneX, Cogent Communications
- name: EdgeConneX, Cogent Communications
- operator: EdgeConneX, Cogent Communications
- province: EdgeConneX, Cogent Communications
- record_kind: EdgeConneX, Cogent Communications
Location
ReportedEdgeConneX markets TOR01 in Toronto; Cogent independently lists it at 565 Gordon Baker Road, North York.
- Evidence date
- Undated source
- Checked
- 2026-10-05
- Scope
- Facility
- Evidence type
- Reported
- Status describes
- Operator marketed facility identity
- EdgeConneX TOR01 Toronto technical data sheet · EdgeConneX
- Toronto service locations, page 2 · Cogent Communications
Permanent claim link · Claim pub-ontario_a-on-122-1
Citation text (select to copy)
Clarion Solutions. EdgeConneX TOR01 / EDCTOR01. Canadian Data Centre Atlas. Record on-122; claim pub-ontario_a-on-122-1. Edition 2026-10-06-83c11c799ab4-public-2026-10-06 (publication date: 2026-10-06); evidence review through 2026-10-06. Claim evidence date: undated; source checked: 2026-10-05. https://data.clarionsolutions.ca/canada-data-centres/editions/2026-10-06-83c11c799ab4-public-2026-10-06/records/on-122/#claim-pub-ontario_a-on-122-1
Cite the linked primary evidence as well. Publication and access dates do not establish current operations.
Capacity
ReportedThe operator’s current sheet specifies 1 MW with N+1 redundancy. It does not explicitly establish the IT-versus-utility basis.
- Evidence date
- Undated source
- Checked
- 2026-10-05
- Scope
- Facility
- Evidence type
- Reported
- Status describes
- Capacity at stated basis and scope
- Quantity type
- Unspecified power
- Basis
- operator technical-sheet rating; basis not explicit
- Reported quantity
- 1 MW
- EdgeConneX TOR01 Toronto technical data sheet · EdgeConneX
Permanent claim link · Claim pub-ontario_a-on-122-2
Citation text (select to copy)
Clarion Solutions. EdgeConneX TOR01 / EDCTOR01. Canadian Data Centre Atlas. Record on-122; claim pub-ontario_a-on-122-2. Edition 2026-10-06-83c11c799ab4-public-2026-10-06 (publication date: 2026-10-06); evidence review through 2026-10-06. Claim evidence date: undated; source checked: 2026-10-05. https://data.clarionsolutions.ca/canada-data-centres/editions/2026-10-06-83c11c799ab4-public-2026-10-06/records/on-122/#claim-pub-ontario_a-on-122-2
Cite the linked primary evidence as well. Publication and access dates do not establish current operations.
Capacity
PlannedThe sheet describes a planned scalable total of 3 MW, not a delivered expansion.
- Evidence date
- Undated source
- Checked
- 2026-10-05
- Scope
- Facility
- Evidence type
- Reported
- Status describes
- Capacity at stated basis and scope
- Quantity type
- Unspecified power
- Basis
- planned scalable total
- Reported quantity
- 3 MW
- EdgeConneX TOR01 Toronto technical data sheet · EdgeConneX
Permanent claim link · Claim pub-ontario_a-on-122-3
Citation text (select to copy)
Clarion Solutions. EdgeConneX TOR01 / EDCTOR01. Canadian Data Centre Atlas. Record on-122; claim pub-ontario_a-on-122-3. Edition 2026-10-06-83c11c799ab4-public-2026-10-06 (publication date: 2026-10-06); evidence review through 2026-10-06. Claim evidence date: undated; source checked: 2026-10-05. https://data.clarionsolutions.ca/canada-data-centres/editions/2026-10-06-83c11c799ab4-public-2026-10-06/records/on-122/#claim-pub-ontario_a-on-122-3
Cite the linked primary evidence as well. Publication and access dates do not establish current operations.
Power
InstalledThe power design is described as concurrently maintainable with at least N+1 PDU, UPS and generator components; fuel and utility agreements are not disclosed.
- Evidence date
- Undated source
- Checked
- 2026-10-05
- Scope
- Facility
- Evidence type
- Reported
- Status describes
- Power supply or backup configuration
- EdgeConneX TOR01 Toronto technical data sheet · EdgeConneX
Permanent claim link · Claim pub-ontario_a-on-122-4
Citation text (select to copy)
Clarion Solutions. EdgeConneX TOR01 / EDCTOR01. Canadian Data Centre Atlas. Record on-122; claim pub-ontario_a-on-122-4. Edition 2026-10-06-83c11c799ab4-public-2026-10-06 (publication date: 2026-10-06); evidence review through 2026-10-06. Claim evidence date: undated; source checked: 2026-10-05. https://data.clarionsolutions.ca/canada-data-centres/editions/2026-10-06-83c11c799ab4-public-2026-10-06/records/on-122/#claim-pub-ontario_a-on-122-4
Cite the linked primary evidence as well. Publication and access dates do not establish current operations.
Cooling
ReportedThe TOR01 sheet specifies a 30-inch underfloor air plenum and N+1 CRAC units in separate suites.
- Evidence date
- Undated source
- Checked
- 2026-10-05
- Scope
- Facility
- Evidence type
- Reported
- Status describes
- Cooling system at stated scope
- EdgeConneX TOR01 Toronto technical data sheet · EdgeConneX
Permanent claim link · Claim pub-ontario_a-on-122-5
Citation text (select to copy)
Clarion Solutions. EdgeConneX TOR01 / EDCTOR01. Canadian Data Centre Atlas. Record on-122; claim pub-ontario_a-on-122-5. Edition 2026-10-06-83c11c799ab4-public-2026-10-06 (publication date: 2026-10-06); evidence review through 2026-10-06. Claim evidence date: undated; source checked: 2026-10-05. https://data.clarionsolutions.ca/canada-data-centres/editions/2026-10-06-83c11c799ab4-public-2026-10-06/records/on-122/#claim-pub-ontario_a-on-122-5
Cite the linked primary evidence as well. Publication and access dates do not establish current operations.
Connectivity
ReportedThe sheet describes diverse entrances and meet-me rooms, naming Beanfield, Bell Canada, Cogeco, Cogent, Hurricane Electric and Zayo. End-to-end physical route independence is not audited.
- Evidence date
- Undated source
- Checked
- 2026-10-05
- Scope
- Facility
- Evidence type
- Reported
- Status describes
- Connectivity infrastructure or service
- EdgeConneX TOR01 Toronto technical data sheet · EdgeConneX
Permanent claim link · Claim pub-ontario_a-on-122-6
Citation text (select to copy)
Clarion Solutions. EdgeConneX TOR01 / EDCTOR01. Canadian Data Centre Atlas. Record on-122; claim pub-ontario_a-on-122-6. Edition 2026-10-06-83c11c799ab4-public-2026-10-06 (publication date: 2026-10-06); evidence review through 2026-10-06. Claim evidence date: undated; source checked: 2026-10-05. https://data.clarionsolutions.ca/canada-data-centres/editions/2026-10-06-83c11c799ab4-public-2026-10-06/records/on-122/#claim-pub-ontario_a-on-122-6
Cite the linked primary evidence as well. Publication and access dates do not establish current operations.